Einige Inhalte auf dieser Seite sind in deutscher Sprache nicht verfügbar und werden automatisch in derzeit verfügbarer Sprache angezeigt.

Staining Mitochondria in Live Cells with LumiTracker® Mito Probes

LumiTracker® Mito probes are cationic, cell-permeant stains with mildly thiol-reactive chloromethyl moiety used for labeling live mitochondria. LumiTracker® Mito probes passively diffuse across the plasma membrane and selectively accumulate in active mitochondria based on their membrane potential. The LumiTracker® Mito probes differ in spectral characteristics and fixability, summarized in the next Table.

Probe Catalog Number MW Ex (nm)* Em (nm)* Oxidation State Kept after Fixation
Rosamine-based
LumiTracker® Mito Orange CMTMRos 2252-x 427.38 555 578 Oxidized Yes
LumiTracker® Mito Orange CM-H2TMRos 4367-x 392.93 Reduced Yes
LumiTracker® Mito Red CMXRos 2251-x 531.53 581 600 Oxidized Yes
Carbocyanine-based
LumiTracker® Mito Green FM 3527-x 671.88 491 513 NA No
LumiTracker® Mito Red FM 3170-x 724.00 590 643 NA No

LumiTracker® Mito probes are primarily intended for use in live cells; however, rosamine-based probes are also kept after fixation and permeabilization during subsequent immunocytochemistry or in situ hybridization processing. Although some mitochondrial labeling can be accomplished in fixed cells with LumiTracker® Mito probes, the signal-to-noise ratios are typically not optimal. If labeling mitochondria in fixed cells is necessary, it is advisable to use anti-OxPhos antibodies.

Before you start

  • The reduced rosamine LumiTracker® Mito probes are sensitive to oxidation, especially in solution, and must be stored under argon or nitrogen at lower −20 °C and protected from light. We recommend using reduced rosamine solutions immediately after their preparation.
  • The commonly used dye concentration to stain cells is 25–500 nM. The working dilution depends on the cell type and density and should be defined experimentally.
  • The reduced rosamine LumiTracker® Mito probes are generally loaded to cells at three- to five-fold higher concentrations than other LumiTracker® Mito probes.
  • The optimal cell density and staining duration may vary by cell type. The staining protocol should be optimized in preliminary experiments for best results.

Stock Solution Preparation

  1. Before opening, each vial should be warm to room temperature.
  2. Dissolve the lyophilized LumiTracker® Mito probe in high-quality, anhydrous dimethylsulfoxide to obtain a 1 mM stock solution.
  3. Mix well until the dye has fully dissolved.
  4. Store the stock solution in small aliquots at −20 °C or −80 °C away from light. Avoid repeated freeze-thaw cycles.

Staining Solution Preparation

  • Dilute 1 mM LumiTracker® Mito stock solution to the final working concentration in the appropriate buffer or culture medium.
    Important! The reduced forms of the LumiTracker® Mito are susceptible to potential oxidases in serum. We do not recommend using complete media with these probes.
  • The commonly used dye concentration to stain cells is 25–500 nM. The working dilution depends on the cell type, density, and application. If stained cells should be fixed and permeabilized, use a working concentration of 100–500 nM.
  • For the LumiTracker® Mito Green FM probe, use a concentration of 20–200 nM. At high concentrations, this probe tends to stain other cellular structures.
    Important! Keep the dye concentration as low as possible to reduce potential artifacts and mitochondrial toxicity from overloading.

Cell Staining

Staining Adherent Cells

  1. Grow cells on a sterile coverslip. Adherent cells can be stained directly on the coverslip.
  2. Remove the media from the dish and add pre-warmed to 37 °C staining solution.
  3. Incubate cells in the dark for 15–45 minutes under growth conditions appropriate for the particular cell type.
  4. Replace the staining solution with fresh pre-warmed media or buffer.
  5. Image cells using a fluorescence microscope or fluorescence microplate reader.

Staining Suspension Sells

  1. Obtain a single-cell suspension.
  2. Centrifuge cells and aspirate the supernatant.
  3. Resuspend the cells gently in a pre-warmed to 37 °C staining solution.
  4. Incubate cells in the dark for 15–45 minutes under growth conditions appropriate for the particular cell type.
  5. Centrifuge cells and aspirate the supernatant.
  6. Resuspend cells in fresh pre-warmed medium or buffer.
  7. Analyze cells using a flow cytometer, fluorescence microscope, or fluorescence microplate reader.
  8. If immobilized cells on coverslips are needed, use poly-L-lysine-coated slides or coverslips before mounting.

Fixation and Permeabilization Cells after Staining

These steps are optional and may be needed for subsequent immunocytochemistry or in situ hybridization processing. Use the protocol described below for rosamine-based probes only. LumiTracker® Mito Green FM and LumiTracker® Mito Red FM are not retained well after fixation.

  1. Wash the cells in fresh, pre-warmed buffer or growth medium after staining.
  2. Carefully aspirate the buffer or medium.
  3. Fix the cells for 15 minutes with fresh 2–4% formaldehyde prepared on buffer or growth medium.
  4. Rinse the cells several times with buffer.
  5. When permeabilization is needed, incubate fixed cells for 10 minutes in PBS containing 0.2% Triton X-100 and then wash in PBS. Alternatively, the cells may be permeabilized by incubating in ice-cold acetone for 5 minutes and then washed in PBS. This acetone-permeabilization step may also be used to improve the signal-to-background ratio.

Ähnliche Produkte

LumiTracker® Mito Green FM

Zellgängiger, kationischer, grün fluoreszierender Farbstoff zur potentialabhängigen Färbung aktiver Mitochondrien in lebenden Zellen.
Preise einblenden
Artikel-Nr. Packungseinheit Preis Vorlaufzeit
3527-50ug 50 ug –   Auf Lager
3527-500ug 500 ug $199 Auf Lager
Einen günstigeren Preis gefunden? Lassen Sie es uns wissen und wir unterbreiten Ihnen ein besseres Angebot!

LumiTracker® Mito Orange CM-H2TMRos

Ein kationischer, orange-fluoreszierender Farbstoff zur Färbung aktiver Mitochondrien in lebenden Zellen. CM-H2TMRos ist eine reduzierte, nicht fluoreszierende Version des CMTMRos-Farbstoffs, die fluoresziert, wenn sie an der Mitochondrienmembran oxidiert wird.
Preise einblenden
Artikel-Nr. Packungseinheit Preis Vorlaufzeit
4367-50ug 50 ug $24 Auf Lager
Einen günstigeren Preis gefunden? Lassen Sie es uns wissen und wir unterbreiten Ihnen ein besseres Angebot!

LumiTracker® Mito Orange CMTMRos

Zellgängiger, kationischer, orange fluoreszierender Farbstoff zur potentialabhängigen Färbung aktiver Mitochondrien in lebenden Zellen. Die Färbung bleibt nach der Aldehydfixierung gut erhalten.
Preise einblenden
Artikel-Nr. Packungseinheit Preis Vorlaufzeit
2252-50ug 50 ug –   Auf Lager
2252-500ug 500 ug $125 Auf Lager
Einen günstigeren Preis gefunden? Lassen Sie es uns wissen und wir unterbreiten Ihnen ein besseres Angebot!

LumiTracker® Mito Red CMXRos

Zellgängiger, kationischer, rot fluoreszierender Farbstoff zur potentialabhängigen Färbung aktiver Mitochondrien in lebenden Zellen. Die Färbung bleibt nach der Aldehydfixierung gut erhalten.
Preise einblenden
Artikel-Nr. Packungseinheit Preis Vorlaufzeit
2251-50ug 50 ug –   Auf Lager
2251-500ug 500 ug $140 Auf Lager
Einen günstigeren Preis gefunden? Lassen Sie es uns wissen und wir unterbreiten Ihnen ein besseres Angebot!

LumiTracker® Mito Red FM

Zellgängiger, kationischer, rot fluoreszierender Farbstoff zur potentialabhängigen Färbung aktiver Mitochondrien in lebenden Zellen.
Preise einblenden
Artikel-Nr. Packungseinheit Preis Vorlaufzeit
3170-50ug 50 ug $35 Auf Lager
3170-500ug 500 ug $199 Auf Lager
Einen günstigeren Preis gefunden? Lassen Sie es uns wissen und wir unterbreiten Ihnen ein besseres Angebot!

Sie haben den Artikel in den Warenkorb gelegt.. Warenkorb ansehen oder zur Kasse gehen
Die eingegebene Zahl ist falsch..